Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ther Apher Dial ; 26(5): 992-998, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34981641

RESUMEN

INTRODUCTION: Hemodialysis (HD) patients should be trained to develop self-care behaviors in order to prevent and preserve their arteriovenous fistula (AVF). The aim of this study was identifying the factors that affect the levels of self-care behavior with AVF by HD patients. METHODS: A cross-sectional study was conducted involving 89 patients. RESULTS: Self-care levels were negatively affected by patients' location (Azores) and positively affected by marital status, education, employment, AVF duration, and absence of complications with the AVF. Concerning the management of signs and symptoms, self-care levels were negatively affected by patients' location. Regarding prevention of complications, self-care levels were negatively affected by age and marital status and positively affected by marital status, employment, chronic kidney disease etiology, AVF duration, and previous AVF. CONCLUSION: Further studies are required in order to confirm whether the considered factors affect levels of self-care behaviors with AVF, or whether other factors are needed as well.


Asunto(s)
Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Fallo Renal Crónico , Estudios Transversales , Demografía , Humanos , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Modelos Logísticos , Diálisis Renal , Estudios Retrospectivos , Autocuidado
2.
Clin Nurs Res ; 30(6): 875-882, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33491487

RESUMEN

The purpose of this study was to evaluate the psychometric properties of the Brazilian Scale for the Assessment of Self-Care Behaviors with Arteriovenous Fistula in Hemodialysis. Cross-sectional validation study, followed the recommendation provided by Sousa and Rojjanasrirat. Content validity, explanatory and confirmatory factor analyses used to check validity and Cronbach's alpha was the reliability measure. Three hundred hemodialysis patients with arteriovenous fistula were included in the study. The expert committee assessed the content validity. Exploratory factor analysis confirmed the same two-factor structure found for the original scale, explaining 60.10% of the variance. Such solution was checked by confirmatory factor analysis with Cronbach's alpha equal to 0.920, 0.810, and 0.884 for the overall scale, the self-care in management of signs and symptoms and the self-care in prevention of complications subscales respectively. The scale has good psychometric properties to assess self-care behaviors and can be used with Brazilian patients on hemodialysis with arteriovenous fistula.


Asunto(s)
Fístula Arteriovenosa , Autocuidado , Brasil , Estudios Transversales , Análisis Factorial , Humanos , Psicometría , Diálisis Renal , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
3.
J Ren Care ; 47(4): 279-284, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33140539

RESUMEN

BACKGROUND: Several guidelines recommend that patients with chronic kidney disease treated by haemodialysis (HD) take care of their own arteriovenous fistula (AVF). The dialysis nurse plays an important role in the development of such self-care behaviours. A very small number of instruments are available to assess self-care behaviours with AVF in Turkey. OBJECTIVE: Cultural adaptation and psychometric testing of the Turkish version of the scale of assessment of self-care behaviours with arteriovenous fistula in haemodialysis (ASBHD-AVF) patients. DESIGN: Cross-sectional validation study. PARTICIPANTS AND MEASUREMENTS: This study was conducted involving 160 patients in the Bolu region in Turkey. The guidelines provided by Sousa and Rojjanasrirat were taken into account in the scale translation, adaptation and validation process. Validity was analysed through content validity and construct validity. The latter was measured through principal component analysis with varimax rotation, considering only factor loadings of 0.30 or larger. Reliability analysis was based on internal consistency measured by Cronbach's α. RESULTS: A two-factor structure was extracted explaining 59.01% of the total variance. Cronbach's α was 0.91, 0.85 and 0.84 for the overall scale, the self-care in prevention of complications subscale and the self-care in management of signs and symptoms subscale, respectively. CONCLUSIONS: The Turkish version of the scale of ASBHD-AVF patients is a reliable and valid instrument and can therefore be used.


Asunto(s)
Fístula Arteriovenosa , Autocuidado , Estudios Transversales , Humanos , Psicometría , Diálisis Renal/efectos adversos , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Turquía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...